Release Note: 04 MAY 1995 
              PM Version 3.0a

1. Two errors are found in the last release of PM
   a. The first line of the river data file MP30RIV.DAT (for MODPATH 3.0)
      was missing. This line must be identical with the first line of the
      file RIV.DAT.

   b. The preprocessor for MT3D gives an error message "subscript out of 
      range...", when one try to edit the ICBOUND array. This error occurs
      only when the number of column is less than 44 and the number of rows
      is less than 8. 

2. To start MODPATH (V3, Release 1, 9-94), please follow the steps below:
   a. Choose MODPATH-Particle tracking from the Computation menu of the 
      PM-shell.
   b. Just press the ENTER key at the following prompt: 
      MODPATH Version 3.00 (V3, Release 1, 9-94)
      TO READ INPUT FROM AN EXISTING RESPONSE FILE, ENTER FILE NAME:
      ( <CR> = ENTER DATA INTERACTIVELY )
   c. Type MPATH30 at the following prompt:
      ENTER THE NAME FILE:
      [ ? = Help ]


-----------------------------------------------------------------------------
Release Note: 03 Feb. 1995 
              PM Version 3.0a

1. To install the Scientific Software Group's version of MODFLOW/EM, 
   MODPATH/EM and MODPATH-PLOT/EM along with PM3.0a, please follow 
   the steps below:
   
   a. INSTALL PM3.0a
      Insert the disk 1 of PM in drive A. At the DOS prompt, change the 
      default drive to A, type INSTALL and press Enter. Choose the options
      [x] BCF2 and [x] Scientific Software's version of MODFLOW. Click <OK> 
      and follow the setup instructions on the screen.
   
   b. INSTALL MODFLOW/EM:
      Insert disk 1 of MODFLOW/EM in drive A. At the DOS prompt, type    
      COPY A:\*.* PMDIR, where PMDIR is the directory where PM3.0a is 
      installed, e.g. C:\PM
   
   c. INSTALL MODPATH/EM
      Insert disk 1 of MODPATH/EM in drive A. At the DOS prompt, type    
      COPY A:\*.* PMDIR, where PMDIR is the directory where PM3.0a is installed.

   d. INSTALL MODPATH-PLOT/EM
      Insert disk 1 of MODPATH-PLOT/EM in drive A. At the DOS prompt, type    
      COPY A:\*.* PMDIR, and insert the following line into AUTOEXEC.BAT:
         
         SET GRAFPRINT=/T:PMDIR
      
      where PMDIR is the directory where PM3.0a is installed.
   
   e. INSTALL MT3D
      To run MT3D, you need a special version of MODFLOW, which is contained 
      in the MT3D software package. While installing PM, you MUST choose the 
      options [x] BCF2 and [x] S.S. Papadopulos's version of MODFLOW.
      After having installed PM3.0a, copy the following files from the 
      MT3D distribution disks to the PM directory:
         MT3D.EXE       The MT3D simulation program
         MODF.EXE       The special version of MODFLOW
         SAVELAST.EXE   A program for extracting the concentration at the last
                        step and save it in the binary file RERUN.UCN. 
   
2. To install the IGWMC's MODFLOW EXT (Version 1.3x) along with PM3.0a, 
   please follow the steps below:
   
   a. INSTALL PM3.0a
      Insert the disk 1 of PM in drive A. At the DOS prompt, change the 
      default drive to A, type INSTALL and press Enter. Choose the options
      [x] BCF2 and [x] IGWMC's version of MODFLOW. Click <OK> and follow 
      the setup instructions on the screen.
   
   b. INSTALL MODFLOW EXT :
      Insert disk 1 of MODFLOW EXT (distributed by the IGWMC) in drive A. Change
      the default drive to A. At the DOS prompt, type 
         
         PKUNZIP MODFLOW.ZIP PMDIR
      
      Where PMDIR is the directory where PM is installed, e.g. C:\PM

         EXAMPLE: PKUNZIP MODFLOW.ZIP C:\PM

      The file MODFLOW.ZIP contains the compressed files and programs of 
      MODFLOW EXT, one of the program (PREMOD.EXE) has the same name as 
      the Preprocessor for MODFLOW provided by PM. PKUNZIP will ask whether 
      or not to overwrite the already existing program PREMOD.EXE, answer N
      at the prompt.
   
   c. INSTALL MODPATH/EM and MODPATH-PLOT/EM
      If you have purchased MODPATH/EM and MODPATH-PLOT/EM separately from 
      the Scientific Software Group, follow the installation step described
      above (1.c and 1.d) to setup these software

   e. INSTALL MT3D
      see 1.e described above

3. To install the S.S. Papadopulos's MODFLOW/MT3D (Version 1.8x) along with 
   PM3.0a, please follow the steps below:
      
   a. INSTALL PM3.0a
      Insert the disk 1 of PM in drive A. At the DOS prompt, change the 
      default drive to A, type INSTALL and press Enter. Choose the options
      [x] BCF2 and [x] S.S. Papadopulos's version of MODFLOW. Click <OK> and 
      follow the setup instructions on the screen.
   
   b. INSTALL MODFLOW and MT3D:
      After having installed PM3.0a, copy the following files from the 
      MT3D distribution disks to the PM directory:
         MT3D.EXE       The MT3D simulation program
         MODF.EXE       A special version of MODFLOW, which works with MT3D
         SAVELAST.EXE   A program for extracting the concentration at the last
                        step and save it in the binary file RERUN.UCN. 
      
   c. INSTALL MODPATH/EM and MODPATH-PLOT/EM
      If you have purchased MODPATH/EM and MODPATH-PLOT/EM separately from 
      the Scientific Software Group, follow the installation step described
      above (1.c and 1.d) to setup these software

4. To run the sample model (EXAMPLE) contained in PM3.0a:
   a. At the DOS prompt, change to the PM directory.
   b. Type PM3 to start PM.
   c. From the PM-Shell, choose "Edit Flow Model"
   d. Choose "Transfer Model Data" from the Premod menu.
   e. Choose "Exit" to leave Premod
   f. Choose "MODFLOW - Simulation"
      The Name File for SSG's MODFLOW is FLOWFILE
   g. Choose "MODPATH - Particle Tracking"
      The Name File for MODPATH/EM (version 1.xx) is PATHFILE
      The Name File for MODPATH/EM (version 3.xx) is MPATH30 

5. PM3.0a supports MODPATH/MODPATH-PLOT Version 3.0 (Release 1, 94-9). 
   a. PM3.0a creates the following data files for the new version of 
      MODPATH and MODPATH-PLOT
      MPATH30:     the Name-File for MPATHEM and MODPATH-PLOT
      MAIN30.DAT:  Main data file for MODPATH V.3.0
      MP30WEL.DAT: Well data file
      MP30RIV.DAT: River data file
      MP30DRN.DAT: Drain data file
      MP30GHB.DAT: General head boundary data file
      MP30STR1.DAT:Stream Flow package data file
      RCH.DAT:     Recharge (Also used by MODFLOW/EM)
      EVT.DAT:     Evapotranspiration (Also used by MODFLOW/EM)
   
   b. By default, PM tells MODPATH/EM to read following resulting files 
      from MODFLOW:
      BUDGET.DAT:  Cell-by-Cell budget file 
      HEADS.DAT:   hydraulic heads at each cell
      DDOWN.DAT:   drawdowns at every cell

   c. By default, the results of MODPATH will be saved in the PM directory 
      by using the following file names, all these files are saved in ASCII:
      ENDPOINT:    Endpoint of particles
      PATHLINE:    Coordinates along the path of each particle are recorded 
                   in this file
      TIMESERS:    The locations of particles at specified points in time are 
                   recorded in this file.

   d. If your model has only one row, PM3.0a automatically creates model data 
      for the 1-row cross-section option (XSECTION) of MODPATH V3.0.

6. A new particle tracking model PMPATH for Windows (Chiang, 1994) is now 
   available. PMPATH is a true Windows application and works with PM3.0x. 
   The program allows users to run particle tracking full interactively, 
   including forward and backward particle tracking (optionally single-step 
   tracking) for steady state and transient flow fields. Graphics output 
   include DXF, HPGL and Windows Bitmap. For more information, please 
   contact 
   a. Scientific Software Group, Fax: +1 (703) 6206793  (USA)
   b. International Ground-Water Modeling Center, Fax: +1 (303) 273 3278 (USA)
   c. C Vision PTY LTD, Fax: +61 (2) 261 4854 (AUSTRALIA)


-----------------------------------------------------------------------------
Release Note: 01 Oct. 1994

1. The PM-shell program PMMAIN.EXE now calls the IGWMC's MODFLOW 
   with the following command: 
     
     MOD-EM<IGWMCFIL 

   Where IGWMCFIL is a response file that contains the names of input 
   and output files in the order required by the IGWMC-MODFLOW 
   Version 1.3 or later. If you want to run the IGWMC-MODFLOW without 
   using the IGWMCFIL file, you have to exit PM and run MODFLOW by
   typing the following command at the DOS-prompt:
     
     MOD-EM

2. The new PMTRANS.EXE program creates the response file IGWMCFIL for 